Parametric Search
AC/DC Flyback Controllers
Filter, sort and export; for parts not yet listed, send an inquiry and our engineers will confirm availability
AC/DC flyback controllers drive the switching timing of an external power switch in flyback-topology power supplies. Compared with integrated solutions, the power device can be selected independently, giving greater design flexibility.
- Requires pairing with an external power switch sized for the target power level, with controller and switch parameters matched
- Modulation mode (PWM/quasi-resonant/PFM) affects efficiency and noise behavior
- Quiescent and start-up current affect no-load power and start-up circuit design
- Protection trip thresholds (overvoltage/short-circuit/overtemp) must meet applicable safety standards
AI Selection Assistant · AC/DC Flyback Controllers
TrialHYASIC
- Series / Type
- Smart peak-power multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 65/
130 - Control Mode
- CCM/
QR/ DCM - Package
- SOT23-6L
- BRWO
- -
- O/P OVP
- -
HYASIC
- Series / Type
- Smart peak-power multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 65/
130 - Control Mode
- CCM/
QR/ DCM - Package
- SOT23-6L
- BRWO
- √
- O/P OVP
- AR
HYASIC
- Series / Type
- Smart multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 65
- Control Mode
- CCM/
QR/ DCM - Package
- SOT23-6L
- BRWO
- √
- O/P OVP
- -
HYASIC
- Series / Type
- Smart multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- CCM/
QR/ DCM - Package
- SOT23-6L
- BRWO
- √
- O/P OVP
- -
HYASIC
- Series / Type
- Smart multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- CCM/
QR/ DCM - Package
- SOT23-6L
- BRWO
- √
- O/P OVP
- AR
HYASIC
- Series / Type
- Smart multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 65
- Control Mode
- CCM/
DCM - Package
- SOT23-6L
- BRWO
- -
- O/P OVP
- -
HYASIC
- Series / Type
- Smart multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 65
- Control Mode
- CCM/
DCM - Package
- SOT23-6L
- BRWO
- -
- O/P OVP
- -
HYASIC
- Series / Type
- Smart multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- CCM/
QR/ DCM - Package
- SOT23-6L
- BRWO
- √
- O/P OVP
- AR
HYASIC
- Series / Type
- Smart multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 130
- Control Mode
- QR
- Package
- SOT23-6L
- BRWO
- √
- O/P OVP
- AR
HYASIC
- Series / Type
- Smart multi-mode flyback controller
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- QR
- Package
- SOT23-6L
- BRWO
- √
- O/P OVP
- AR
HYASIC
- Series / Type
- Smart multi-mode flyback controller with external OTP function
- Max. Switching Frequency (kHz)
- 65
- Control Mode
- CCM/
QR/ DCM - Package
- SOP-7L
- BRWO
- √
- O/P OVP
- -
HYASIC
- Series / Type
- Smart multi-mode flyback controller with external OTP function
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- CCM/
DCM - Package
- SOP-7L
- BRWO
- √
- O/P OVP
- -
HYASIC
- Series / Type
- Smart multi-mode flyback controller with external OTP function
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- CCM/
QR/ DCM - Package
- SOP-7L
- BRWO
- √
- O/P OVP
- -
HYASIC
- Series / Type
- Smart multi-mode flyback controller with external OTP function
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- QR
- Package
- SOP-7L
- BRWO
- √
- O/P OVP
- -
HYASIC
- Series / Type
- Smart multi-mode flyback controller with external OTP function
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- CCM/
QR/ DCM - Package
- SOP-7L
- BRWO
- √
- O/P OVP
- -
HYASIC
- Series / Type
- Smart multi-mode flyback controller with external OTP function
- Max. Switching Frequency (kHz)
- 200
- Control Mode
- QR
- Package
- SOP-7L
- BRWO
- √
- O/P OVP
- AR
HYASIC
- Series / Type
- Smart multi-mode flyback controller directly driving GaN devices
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- CCM/
QR/ DCM - Package
- SOT23-6L
- BRWO
- -
- O/P OVP
- √
HYASIC
- Series / Type
- Smart multi-mode flyback controller directly driving GaN devices
- Max. Switching Frequency (kHz)
- 130
- Control Mode
- QR/
DCM - Package
- SOT23-6L
- BRWO
- -
- O/P OVP
- √
HYASIC
- Series / Type
- Smart multi-mode flyback controller directly driving GaN devices
- Max. Switching Frequency (kHz)
- 89
- Control Mode
- CCM/
QR/ DCM - Package
- SOP-7L
- BRWO
- √
- O/P OVP
- √
HYASIC
- Series / Type
- Smart multi-mode flyback controller directly driving GaN devices
- Max. Switching Frequency (kHz)
- 130
- Control Mode
- QR/
DCM - Package
- SOP-7L
- BRWO
- √
- O/P OVP
- √
HYASIC
- Series / Type
- Smart multi-mode flyback controller directly driving GaN devices
- Max. Switching Frequency (kHz)
- 200
- Control Mode
- QR/
DCM - Package
- SOP-7L
- BRWO
- √
- O/P OVP
- √
| Brand | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| HYASIC | Smart peak-power multi-mode flyback controller | 65/130 | CCM/QR/DCM | SOT23-6L | - | - | Latch 38V/Latch | - | - | - | |
| HYASIC | Smart peak-power multi-mode flyback controller | 65/130 | CCM/QR/DCM | SOT23-6L | √ | AR | 38V/AR | - | - | √√ | |
| HYASIC | Smart multi-mode flyback controller | 65 | CCM/QR/DCM | SOT23-6L | √ | - | Latch 38V/Latch | - | √√√ | AR | |
| HYASIC | Smart multi-mode flyback controller | 89 | CCM/QR/DCM | SOT23-6L | √ | - | Latch 38V/Latch | - | √√√ | - | |
| HYASIC | Smart multi-mode flyback controller | 89 | CCM/QR/DCM | SOT23-6L | √ | AR | 38V/AR | - | √√ | - | |
| HYASIC | Smart multi-mode flyback controller | 65 | CCM/DCM | SOT23-6L | - | - | 30V/AR | - | √ | - | |
| HYASIC | Smart multi-mode flyback controller | 65 | CCM/DCM | SOT23-6L | - | - | 38V/Latch | - | √ | √ | |
| HYASIC | Smart multi-mode flyback controller | 89 | CCM/QR/DCM | SOT23-6L | √ | AR | 55V/AR | √ | - | √ | |
| HYASIC | Smart multi-mode flyback controller | 130 | QR | SOT23-6L | √ | AR | 55V/AR | √ | - | √ | |
| HYASIC | Smart multi-mode flyback controller | 89 | QR | SOT23-6L | √ | AR | 55V/AR | √ | √ | √ | |
| HYASIC | Smart multi-mode flyback controller with external OTP function | 65 | CCM/QR/DCM | SOP-7L | √ | - | AR 55V/AR | - | √ | - | |
| HYASIC | Smart multi-mode flyback controller with external OTP function | 89 | CCM/DCM | SOP-7L | √ | - | AR 55V/AR | - | √√√ | - | |
| HYASIC | Smart multi-mode flyback controller with external OTP function | 89 | CCM/QR/DCM | SOP-7L | √ | - | AR 55V/AR | - | √ | √ | |
| HYASIC | Smart multi-mode flyback controller with external OTP function | 89 | QR | SOP-7L | √ | - | AR 55V/AR | - | √ | √ | |
| HYASIC | Smart multi-mode flyback controller with external OTP function | 89 | CCM/QR/DCM | SOP-7L | √ | - | AR 55V/AR | - | √√ | - | |
| HYASIC | Smart multi-mode flyback controller with external OTP function | 200 | QR | SOP-7L | √ | AR | 55V/AR | - | √ | - | |
| HYASIC | Smart multi-mode flyback controller directly driving GaN devices | 89 | CCM/QR/DCM | SOT23-6L | - | √ | AR 38V/AR | - | √ | √√ | |
| HYASIC | Smart multi-mode flyback controller directly driving GaN devices | 130 | QR/DCM | SOT23-6L | - | √ | AR 38V/AR | - | - | √√ | |
| HYASIC | Smart multi-mode flyback controller directly driving GaN devices | 89 | CCM/QR/DCM | SOP-7L | √ | √ | AR 55V/AR | - | - | √√ | |
| HYASIC | Smart multi-mode flyback controller directly driving GaN devices | 130 | QR/DCM | SOP-7L | √ | √ | AR 55V/AR | - | - | √ | |
| HYASIC | Smart multi-mode flyback controller directly driving GaN devices | 200 | QR/DCM | SOP-7L | √ | √ | AR 55V/AR | √ | √ | √ |